Constructed of solid brass to handle tough conditions and resist contamination.
An internal self-flushing filter and self-cleaning metering rod help eliminate dirt particles before they enter the solenoid chamber, effectively making this valve contamination-resistant. The HBV also features a stainless steel solenoid seat, built-in flow control to assure accurate flow management, and a surgical-quality toggle switch that provides easy manual operation through internal downstream bleed. So rugged and reliable, dirty water will never be a problem again!
HBV MODELS
HBV-101E – 1" brass globe valve
HBV-151E – 1 1/2" brass globe valve
HBV-201E – 2" brass globe valve
HBV-301E – 3" brass globe valve
DIMENSIONS
• HBV-101E – 4 1/2" H x 4 3/8" L x 5 1/2" W (11 cm H x 11 cm L x 14 cm W)
• HBV-151E – 8" H x 6" L x 8" W (20 cm H x 15 cm L x 20 cm W)
• HBV-201E – 9" H x 7" L x 9" W (23 cm H x 18 cm L x 23 cm W)
• HBV-301E – 10" H x 11 5/8" L x 10" W (25 cm H x 29 cm L x 25 cm W)
• HBV-101EP – 4 1/2" H x 4 3/8" L x 5 1/2" W (11 cm H x 11 cm L x 14 cm W)
• HBV-151EP – 8" H x 6" L x 7 1/2" W (20 cm H x 15 cm L x 19 cm W)
• HBV-201EP – 9" H x 7" L x 7 3/4" W (23 cm H x 18 cm L x 20 cm W)
• HBV-301EP – 10" H x 11 5/8" L x 11" W (25 cm H x 29 cm L x 28 cm W)
• Female inlet/outlet: NPT or BSP
OPERATING SPECIFICATIONS
• Flow: 5 to 360 GPM (1.14 to 81.8 m3/hr; 18.9 to 1362 I/min)
• Pressure: 20 to 200 PSI (1.4 to 14.0 bars; 138 to 1379 kPa)
Note: Inlet pressure must exceed outlet pressure by a minimum of 15 PSI
(1.0 bars; 103 kPa) on pressure regulated models
• Electrical: 24VAC, 50/60 cycle solenoid power requirement –
335mA (.335A; 8VA) inrush current; 200mA (.200A; 4.9VA) holding current
OPTIONS AVAILABLE
• Pressure regulation
• BSP threads
• 12-volt DC latching solenoid, field installed (part # S16305)